U-Test 300 Test Head
Test Heads > U-Test 300
Product Data
Summary of Technical Specification
- Built on a powerful linux platform
- Published API for direct connection
- TL1 switching protocol
- XML web services interface
- Custom interface available
- Automatic discovery
DC voltage tests
- Range: -440 to +440 volts
- Accuracy: ± 2%
- Resolution: 1 volt
-
Tests performed:
B-leg/Earth
A-leg/Earth
B-leg/A-leg
AC voltage tests
- Range: 0 to 300 volts RMS
- Frequency: 20Hz to 1kHz
- Accuracy: ± 2%
- Resolution: 1 volt
-
Tests performed:
B-leg/Earth
A-leg/Earth
B-leg/A-leg
Dangerous Voltage Threshold - User defined
Resistance tests
- Range: 0 Ω to 100 Ω
- Accuracy: ± 3 Ω
- Range: 100 Ω to 10M Ω
- Accuracy: ± 3%
- Resolution: 1 Ω
-
Tests performed:
A-leg/Earth
B-leg/Earth
B-leg/A-leg
A-leg/B-leg (Reversed Loop)
A-Battery
B-Battery
Capacitance tests
- Range: 0nF to 100n μ F
- Accuracy: ± 3nf
- Range: 100nF to 10 μ F
- Accuracy: ± 3%
- Resolution: 1nF
-
Tests performed:
B-leg/Earth
A-leg/Earth
B-leg/A-leg
Exchange or Central Office tests
- Line Circuit conditions
- Draw Dial Tone
- MF4 Dialling
Noise Tests
- Range: 10KHz to 2.2 MHz
- Accuracy: ± 50Hz
- Level: 0dB to -40dB (10Khz to 2.2MHz)
- Accuracy: ± 1.0dB
- Phsometric Weighted Filter Display
- Filter: C/E/F/G or No Filter
Longitudinal balance
- Range: 10KHz to 2.2 MHz
- Accuracy: ± 3db
Frequency Level Tests
- Range: 300Hz to 80kHz
- Accuracy: ± 10Hz
- Level: –40dB to +10dB (0 to 80kHz)
- Accuracy: ± 1.0dB
TDR
- Distance: 4Km (Dependent on Cable Characteristics)
- Pulse Width 30ns to 20us
Tones Generated
- Transmission test tone: 300Hz to 80kHz
- Level: -40dB to 0 dB
- Pair identification tone: 300Hz to 3.4kHz
- Howler: Consecutive application of 2.5kHz, 1.616kHz, 1.982kHz and 1.25kHz
- Intrusion tone: 2kHz
Termination Test and Identification
- Customer premises line termination
- Off-hook telephone
- Telephone Connected
- NTE only no Telephone connected
- BB Modem
Communications Interface
Dimensions
- Size (HxWxD): 25x425x150 millimetres
Supply voltage
- DC supply: 36 to 72 volts
Power consumption
- Idle power: 10W
- Maximum Power: 35W
- Includes power for UTEL TAM and Vonaq VDSL Options
Operating environment
- Temperature range: -30 C to 65 C
- Humidity range: 0% to 95% non-condensing
Reliability
- MTBF: Greater the 35 years
Product approvals and standards
- CE approved: Electromagnetic emissions
- Safety standards: IEC 1010-1, EN41
Please click here to contact us for further information